Scanner settings

The Scanner window ranks the whole market at the replay clock and shows the rows of one saved scan. It has no settings dialog of its own: its sliders button opens that scan in the scan builder on the Scanner page, where the filters, ranking, columns, colors, sound and row density are set. Those are saved on the scan in your account, so every Scanner window showing that scan follows, while the scan a window shows and its link group are kept for that window, with the layout.

Where the settings are

In a Scanner window, pick a scan, then click the sliders button at the right end of the header; its tooltip reads Configure scan. You can also click Scanner in the left rail and pick the scan under Toplists, or New toplist for a blank one. Ctrl+J, or ⌘J on a Mac, brings the Scanner window to the front; on a new account's desk it is a tab behind the daily chart. In the builder nothing changes on the scan until you click Save. The header's two sound buttons, and a column you click, drag or resize in the window, save to the scan at once.

The window at a glance

The Scanner window showing the Top Gainers scan at 9:40 a.m. New York time: a table of stocks ranked by percent change, with colored cells and one row marked Viewing. Eight parts are numbered.
  1. The scan menu lists your saved scans, and the choice is kept for this window. Until you pick a scan it sits in the middle of the window.
  2. Sound on new hits, the speaker. It turns the scan's sound on or off and saves at once. The small arrow beside it opens the list of sounds.
  3. As of: the replay time the rows were ranked at, which is the last closed minute.
  4. The link group, the chain button. It sets which windows a clicked row sends its stock to.
  5. Configure scan, the sliders button. It opens this scan in the scan builder.
  6. Click a column name to rank the scan by that column, and again to flip the direction. Drag a name to move its column, or its right edge to set the width. Each change is saved on the scan at once.
  7. Viewing marks the row of the stock this window's link group is showing.
  8. Click a row to show that stock in the windows of this window's link group. A stock not yet in the replay is added at the current replay time.

The scan builder

The scan builder with the Top Gainers scan open on its Filters tab: the name and Save along the top, Rank by and one filter on the left, and a preview table of matching stocks on the right. Ten parts are numbered.
  1. Scan name: the Scanner window's menu and the Toplists list show it.
  2. Nothing changes on the scan until you click Save. The button stays gray until the scan has a name, at least one finished filter and a change to save.
  3. Preview date and Preview time: the day and the minute the preview tests the draft on. The buttons beside them set the time.
  4. Duplicate copies the saved scan under the same name with (copy) added, and opens the copy.
  5. Delete scan, the bin, deletes the saved scan at once, with no confirmation.
  6. Rank by: the metric the scan is ranked by, and its direction. Under it, Show the top sets how many rows the scan shows.
  7. The tabs: Filters, Columns and Settings. Each has its own section below.
  8. A filter: its metric, then a comparison and a value, with preset buttons under them. Every filter must pass for a stock to make the list.
  9. Add filter opens a searchable list of metrics, and each pick adds a row. A scan holds up to 16 filters.
  10. The preview runs the draft on one past minute, in the draft's own columns and colors, and lists up to 50 rows.

Window header

The header holds these from left to right. The sound buttons and the sliders button appear once a scan is picked.

Table header and rows

A change you make on the table's header is saved on the scan at once, with no Save button, and every window showing the scan follows.

Lines under the table say when Show the top is hiding matches, when the scan is ranked by a metric that is not one of its columns, and when a new ranking has to wait for the next scan.

Right-click menu

Right-clicking the header does nothing special in this window, because it has no settings dialog. Right-click the window's tab for the menu every window has.

Scan builder: top bar

Start from a template: Launch set

Start from a template shows on a new scan only. Picking a template fills the draft with its filters, ranking and columns, and nothing is saved until you click Save. Every template looks at Stocks only, on every exchange, and shows the same core columns, painted with the built-in color themes. The scans on the Launch set shelf are also saved on every new account.

Start from a template: other shelves

These are offered in the menu but not saved for you. Each entry starts with the shelf it sits on.

Rank by

Rank by sits above the tabs.

Filters tab

Every filter must pass for a stock to make the list. A new scan reads Empty scan. Add a filter. A filter row has no printed labels, so its parts are named here by what they hold.

Some metrics need a minimum number of shares traded today. When a filter or the rank-by metric has one, a line under the filters tells you, starting Only showing stocks with at least. Columns never set it.

Columns tab

The builder's preview can also show a Date column. A Scanner window never draws one, because it covers one day.

Color themes editor

A color theme paints each cell of a column by its value. You set colors at a few values, called stops, and the cells between them blend. Themes are listed under Colors in the Scanner sidebar and are saved to your account. Every account starts with Change, Volume, Float, Short interest and Relative volume.

Settings tab

Preview

The preview is on the right of a wide window, and under the builder on a narrow one. It runs the draft on one past minute, in the draft's own columns and colors, and runs again about a second after you stop editing. It lists up to 50 rows, and reads First 50 shown when more match. It needs at least one finished filter.

Good to know